COPPG_BEAT_DETECTOR
- COPPG PPG beat detector.
COPPG_BEAT_DETECTOR detects beats in a photoplethysmogram (PPG) signal using the 'Percentile Peak Detector' beat detector
Inputs
-
sig : a vector of PPG values
-
fs : the sampling frequency of the PPG in Hz
Outputs
-
peaks : indices of detected pulse peaks
-
onsets : indices of detected pulse onsets
Reference
C. Orphanidou et al., 'Signal-quality indices for the electrocardiogram and photoplethysmogram: derivation and applications to wireless monitoring,' IEEE Journal of Biomedical and Health Informatics, vol. 19, no. 3, pp. 832-8, 2015. https://doi.org/10.1109/JBHI.2014.2338351
Author
Adapted by Peter Charlton from code supplied by Christina Orphanidou. With grateful thanks to Christina Orphanidou and Alexander Darrell.
Documentation
https://ppg-beats.readthedocs.io/
Version
1.0
Source
-
Original source: https://github.com/peterhcharlton/RRest/blob/master/RRest_v3.0/Algorithms/extract_resp_sig/feat_based_extraction/COr_peak_detector/co_ppg_peak_detector.m , part of the RRest (http://github.com/peterhcharlton/RRest/) repository which is covered by the GNU public licence.
-
Modifications from original by PC: (i) Removed pre-processing; (ii) Hard-coded constants
License - GPL-3.0
This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version.
This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.
You should have received a copy of the GNU General Public License along with this program. If not, see <https://www.gnu.org/licenses/>.